Appendix A Warning and Information Messages A-5
Recognizing Status Notification or Fault Information in a Monitoring
Message on the XSCF Shell Terminal
1. The user recognizes status notification or fault information in a XSCF monitoring
message output by using showmonitorlog(8) comannd. The following shows an
example of the XSCF monitoring message.
(The example is subject to change without previous notice for functional improvement.)
2. To obtain more detailed information, specify the error option and perform the
showlogs(8) command to identify fault information.
3. In the XSCF error log, confirm the contents of entry corresponding to the fault. (See
Appendix B.)
4. Specify the error detail option in showlogs(8) to display the message ID (MSG-ID).
The information can be confirmed by accessing the specified URL according to the
displayed message ID (MSG-ID). Authorized service personnel use the DIAGCODE
(Code) output in the message to acquire more detailed information.
5. Repair the fault according to the processing recommended by the information
provided on the specified URL.
Jun 16 12:20:37 JST 2005 FF2-5-0:Alarm:/CMU#0/CPU#0:XSCF:Uncorrectable error
( 80006000-20010000-0108000112345678)