Cooper Menvier 100 Informations techniques

Naviguer en ligne ou télécharger Informations techniques pour Systèmes de contrôle d'accès de sécurité Cooper Menvier 100. Cooper Menvier 100 System information Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - Fire Systems

UL Listed RangeFire Systems

Page 2 - ONE COOPER

10Code ULDPTR6000Description Repeater Panel, Touch ScreenStandards UL864 9thedition, NFPA 70-72System IndicatorsLED’s Power on, Alarm, General Trouble

Page 3 - Contents

UL Product Range11Addressable SensorsAddressable Sensor, Optical (UCAP320)Addressable Sensor, Opto-Heat (UCAPT340)Addressable Sensor, Multi-Mode Heat

Page 4 - About us

12Code UCAP320 UCAPT340 UCAH330Description Addressable Sensor, Optical Addressable Sensor, Opto-Heat Addressable Sensor, Multi-Mode HeatStandards UL2

Page 5

UL Product Range13UCAB300 Addressable Sensor BaseOverviewThe UCAB300 has been specifically designed to becompatible with UL range of analogue sensors.

Page 6 - Dimensions (Plastic)

14InstallationWiring Hints• Each terminal is suitable for clamping up to 2 wires.• Clamping of 2 wires of very different diametersunder one screw is n

Page 7

UL Product Range15Conventional DetectorsOverviewPhotoelectric smoke detector (opto) is suitable formost applications giving the fastest response to sl

Page 8 - Standard Connections

16Code UCPD-2W UCPT-2W UCHT-2W UCHTI-2W UCHR-2W UCHRI-2WDescription Conventional Detector Conventional Detector Conventional Detector Conventional D

Page 9

UL Product Range17CB2E & CB Conventional Detector BasesOverviewThe CB2E and CB have been specifically designed to be compatible with UL range of c

Page 10 - Mounting the Backbox

18InstallationWiring Hints• Each terminal is suitable for clamping up to 2 wires.• Clamping of 2 wires of very different diametersunder one screw is n

Page 11 - Addressable Sensors

UL Product Range19Addressable Pull StationsOverviewThis range of manual pull stations are constructedof high quality, die-cast metal for long lastingp

Page 12

2ONE COOPEREvery day, thousands of people all over the world use products made by CooperIndustries. As a premier global manufacturing company, we beli

Page 13 - UL Product Range

20Code DescriptionUMPS-100 Pull Station, SPST Single Action, Terminals, Key Reset +ULMCIM-CUMPS-400X Pull Station, Explosion Proof, Single Action, Key

Page 14 - Installation

UL Product Range21OverviewThe UL range of notification devices are designedto exceed your expectations and offer the mostpolished, feature rich and co

Page 15 - Conventional Detectors

22Code DescriptionHNR Horn, Wall Mount, Snap Base, up to 105 dB @ 1meterHNWC Horn, Ceiling Mount, Snap Base, up to 105 dB @ 1meterProduct CodesCode HN

Page 16

UL Product Range23HSR & HSWC Horn StrobesOverviewThe UL range of notification devices are designedto exceed your expectations and offer the mostpo

Page 17

24Code DescriptionHSR Horn Strobe, Wall Mount, Snap Base, 153075100cd up to 105 dB @ 1meterHSWC Horn Strobe, Ceiling Mount, Snap Base,153075100cd up t

Page 18

UL Product Range25STR & STWC Synchronised StrobesOverviewThe UL range of notification devices are designedto exceed your expectations and offer th

Page 19 - Addressable Pull Stations

26Code DescriptionSTR Synchronization Strobe, Wall Mount, Snap Base, 153075110cd STWC Synchronization Strobe, Ceiling Mount Snap Base, 15307595cd Pr

Page 20

UL Product Range27RSSWP-2475W-FR & RSSWP-2475C-FW Synchronised Strobes, OutdoorOverviewThe UL range of notification devices are designedto exceed

Page 21 - HNR & HNWC Horns

28Code DescriptionRSSWP-2475W-FR Synchronization Strobe, Wall Mount, Outdoor, 75cd RSSWP-2475C-FW Synchronization Strobe, Ceiling Mount, Outdoor, 7

Page 22 - HNR & HNWC - Horns

UL Product Range29ULCS354 4 Way Sounder Controller UnitOverviewAn extensive range of interfaces are available tosupport the Menvier range of UL contro

Page 23 - HSR & HSWC Horn Strobes

3Contents4 Introduction5 Control Panels7 Repeater Panels 11 Addressable Sensors15 Conventional Detectors19 Addressable Pull Stations21 Horns/Strobes29

Page 24 - HSR & HSWC - Horn Strobes

30Note:1. The end of line resistors must always be fitted,even if the sounder circuits are unused. Installer /service engineer must ensure it is fitte

Page 25

UL Product Range31ULCZMU352 Zone Monitor UnitOverviewAn extensive range of interfaces are available tosupport the Menvier range of UL control panels,p

Page 26 - Dimensions - Ceiling

32Note:1. This unit can only be used with Menvier ULCB2E or ULCB (CB) detector base and compatibledetectors.2. The end of line resistor must always be

Page 27

UL Product Range33ULCSUM355 Shop Monitor UnitOverviewAn extensive range of interfaces are available tosupport the Menvier range of UL control panels,p

Page 28 - Candela Ratings

34Note:1. The end of line resistor must always be fitted, evenif the inputs are unused. 2. Recommended cable type FPLP (plenum cable),type FPLR (riser

Page 29

UL Product Range35ULCSI350 Spur Isolator UnitOverviewAn extensive range of interfaces are available tosupport the Menvier range of UL control panels,p

Page 30

36Note:1. This unit can only be used with Menvier UCAB300and WBA detector bases and compatible detectors.2. Recommended cable type FPLP (plenum cable)

Page 31 - ULCZMU352 Zone Monitor Unit

UL Product Range37ULCIO351 3 Channel I/O UnitOverviewAn extensive range of interfaces are available tosupport the Menvier range of UL control panels,p

Page 32 - ULCZMU352 - Zone Monitor Unit

38Installation1. Separate the two halves of the unit.2. Drill out (or knock out) the required cable entries in the surface mounting back-box.3. Fit th

Page 33 - ULCSUM355 Shop Monitor Unit

UL Product Range39ULCMIO353 120 V / 230 V Relay UnitOverviewAn extensive range of interfaces are available tosupport the Menvier range of UL control p

Page 34 - ULCSUM355 - Shop Monitor Unit

4About usCooper Safety Fire SystemsCooper Fire offers a comprehensive rangeof UL listed fire detection productssuitable for a wide range of projects,

Page 35 - ULCSI350 Spur Isolator Unit

40Note:1. The end of line resistor must always be fitted, evenif the inputs are unused. Installer / service engineermust ensure it is fitted.Descripti

Page 36 - ULCSI350 - Spur Isolator Unit

UL Product Range41ULMIU872 Micro Zone Monitor UnitOverviewAn extensive range of interfaces are available tosupport the Menvier range of UL control pan

Page 37 - ULCIO351 3 Channel I/O Unit

WHD42Note:1. This unit can only be used with conventionaldetector base and compatible detectors.2. Only connect cable screen to its adjacent earthterm

Page 38 - ULCI0351 - 3 Channel I/O Unit

UL Product Range43ULMCOM & ULMCOM-S Mini Single Channel Output UnitsOverviewAn extensive range of interfaces are available tosupport the Menvier r

Page 39

44Code DescriptionULMCOM Mini Single Channel Output Unit (recognised as output unit)ULMCOM-S Mini Single Channel Output Unit (recognised as sounder)U

Page 40 - CIRCUITS

UL Product Range45ULMCIM & ULMCIM-C Mini Single Channel Input UnitsOverviewAn extensive range of interfaces are available tosupport the Menvier ra

Page 41

46Code DescriptionULMCIM Mini Single Channel Input Unit (recognised as input unit)ULMCIM-C Mini Single Channel Input Unit (recognised as callpoint)UL

Page 42 - Detectors

UL Product Range47Conditions of saleAll goods supplied are subject to the company’s generalconditions of sale which are available on request.Trade Des

Page 43

The trade names and brand names contained herein are valuble trademarks of Cooper Industries in the U.S. and other countries. You are not permitted to

Page 44 - Wiring Class Class A Style 7

UL Product Range5OverviewThe Menvier ULDF6000 is a high specificationanalogue, wall or rack mounted, UL Listed fire systemavailable in various loop co

Page 45

ULDF6000 & ULDF6000RM Control Panels6Code DescriptionULDF60002G 2 Loop PanelULDF60004G 4 Loop PanelULDF60002GP 2 Loop Panel c/w Integral PrinterUL

Page 46

UL Product Range7ULDF6000PR Passive Repeater PanelOverviewThe ULDF6000PR passive repeater panel, is a costeffective system which can be programmed via

Page 47

8Standard ConnectionsDimensions12345D2WHD1H (mm) W (mm) D (mm)395 332 115Code DescriptionULDF6000PR Passive Repeater PanelProduct CodesCode ULDF6000P

Page 48

UL Product Range9ULDPTR6000 Network Repeater Panel, Touch ScreenOverviewThe ULDPTR6000 repeater panel providessophisticated ‘touch screen’ functionali

Commentaires sur ces manuels