Menvier40/100 Technical Specification
Page 31
Capacities (Menvier100)
Expanders and
Wired Keypads
45 max devices (see note)
10 max (two per radio
expander)
10 max (two per radio
expander)
10 max (two per radio
expander, repeater mode
only)
Up to 1,250 events: 1,000
mandatory events, 250 non-
mandatory. Stored in
EEPROM memory, available
for at least 10 years without
power.
250 (plus installer code)
Note: Wired keypads, wired zone
expanders, and radio zone expanders are
all bus devices. You can connect any
combination of these devices to the bus.
Capacities (Both)
16 plug-by communicator
outputs plus 3 wired on
control unit (two transistor
and one relay)
4 transistor based on each
wired expander
8 radio outputs on each
768/769
2 radio outputs on each 762
5 max (two per radio
expander)
1 on control unit, one per
expander
Plug on
communication
modules
±10 minutes over one year.
Notes:
1. Wired keypads, wired zone expanders,
and radio zone expanders are all bus
devices. You can connect any
combination of these devices to the bus.
2. The system can be used as EITHER a
ward based system OR a part setting
system. When used as a part setting
system there are four setting levels
available: Full Set and Part Sets B, C and
D.
Security
10,000 differs with 4 digit
codes.
1,000,000 differs with six
digit codes.
All digits may be any
number 0 to 9.
Blocked for 90s after 10
incorrect codes in series.
Power Supply
This product complies with the requirements of
EN50131-6 Type A power supply at Grade 3 and
environmental class 2.
Mains power supply
requirements
230VAC +10%/-15%,
170mA max, 50Hz.
Total power supply
capacity:
1.5A
(of which 750mA is
used for battery
recharge and 750mA
is available for
powering the
system).
*Note: The ratings given here represent the
maximum current that can be drawn before
triggering over-current protection.
EN50131-6 ratings
The control unit provides space for one
17Ah battery.
Under EN50131-6 for Security Grade 3
installations the required battery standby
time is 60 hours. However, with an ATS4
Commentaires sur ces manuels