16 496574
UK
3. Installation
Surface Magnet
225mm
225mm
Surface Contact
Flush contact block.
(Bore hole 19mm diam
by 16mm deep. Flange
to be flush.)
Flush magnet block.
(Bore hole 19mm diam
by 16mm deep. Flange
to be flush.)
9mm max
9mm max
19mm
16mm
Figure 7. Top Fitting
Surface Magnet Flush Magnet
Flush Contact
Surface Contact
Feed connecting wires
through architrave
Feed connecting wires
through architrave
Figure 8. Bottom Fitting
Fitting PIR Detectors
When fitting typical passive infrared detectors, consult installation instructions
and technical data supplied with the unit.
Fitting The External Sounder
(a) Run the 6 core cable to the agreed position of the bell. Run the cable
directly through the wall into the back of the bell casing. Do not run
surface wiring to the bell as this will compromise the security of the
system.